Compliar holds commissioning, handover and service records for access control and door entry systems. Record the controllers, readers and door releases on site, get the customer's signature, and send a branded PDF from the job.

BOOK A DEMO · NO CONTRACT · EARLY ADOPTERS LOCK THEIR PRICE FOR 3 YEARS
BS EN 60839-11-1
Access control recordsTemplate set
COMMISSIONCommissioning recordInstall
HANDOVERHandover & acceptanceCustomer sign-off
SERVICEService recordEach visit
DEFECTFault to quoteFrom a failed item
What's included

Controllers, readers and releases, door by door

Access control faults are usually found at one door. Holding the controllers, readers and releases as assets on the site keeps their history together from visit to visit.

EquipmentWhat is recorded
ControllersWhere each controller is and what it controls, with a result per visit.
Readers and keypadsEach reader or keypad and whether it was tested and passed.
Door releasesLocks, magnets and strikes, including the fail-safe behaviour you checked.
HandoverA shared handover and acceptance record, signed by the customer.
On the visit

Work down the doors, record as you go

On site

The field app runs in your phone's browser and keeps working with no signal, so a plant room or a basement door is no problem.

Defects

A failed reader or release is raised as a defect and quoted without re-typing, then tracked until it is resolved.

Customer view

Reports can be emailed from the job, and a customer portal login can show the customer their reports once issued.

Good to know

What to record on an access control system

BS EN 60839-11-1 covers electronic access control systems, and your specification may name further requirements. Record the standard or specification you worked to on the commissioning record.

On commissioning and on service, the checks that matter most are usually at the door: that the reader reads, that the release operates and relocks, that the door closes and holds as intended, and that exit routes work. Where the access control system is linked to the fire alarm, check how the doors behave on alarm and record the result.

Compliar keeps the records. The engineer and the customer remain responsible for the system and for how it is used.

The same system covers 32 system types across fire protection and life safety, security and electrical, so one login handles the whole company. See the full list of disciplines.

What to check

Doors that release, doors that hold, and the fire alarm

General guidance only. BS EN 60839-11-1 covers electronic access control systems; BS 7273-4 covers how electrically locked doors on escape routes release on a fire alarm. Check the editions your specification names and your scheme document. Last reviewed 3 November 2026.

The question that matters most

Every electrically locked door on an escape route has to release when people need to get out, and BS 7273-4 is the standard for how that is arranged with the fire detection and alarm system. It describes categories of actuation, from doors that release on any fire signal to doors that release only on a local one, and the design decides which applies to each door. The commissioning record should name the category for each door and the check that it releases as intended, with the fire alarm actually operated rather than simulated. That is the item a fire risk assessor or a scheme auditor goes straight to.

Commissioning, door by door

  • Reader and credential. Valid credential opens, invalid does not, and the event is logged with the right door name.
  • Release and relock. The lock, magnet or strike releases on a valid read and on the request-to-exit device, and relocks within the set time.
  • Fail-safe or fail-secure. What the door does on power loss, and whether that is what the escape route needs.
  • Emergency release. Break-glass or green box at the door operates the release directly, not through the controller.
  • Fire alarm interface. Operate the fire alarm and confirm each door releases per its category, then confirm it relocks on reset only where that is intended.
  • Door closer and monitoring. The door closes and latches on its own, and door-forced and door-held-open alarms report correctly.
  • Controller and power. Controller location, what it serves, standby battery and the network or cabling it depends on.

Worked example

On the Harbourview sample site there are eight controlled doors on two controllers. On the annual visit the engineer works down the doors from the asset list on the phone, recording the read, release, relock and emergency-release checks for each. With the site's fire detection and alarm system on test, a call point is operated and each escape-route door is checked for release; the plant room door, which is not on an escape route, is confirmed to hold. The first-floor fire door magnet holds after the alarm: it is marked Fail with a photo and becomes a defect with a Needs quoting status. The service record with the open defect goes to the customer from the job the same day.

Common mistakes

  • Testing the fire interface from the controller. Simulating the input proves the controller logic, not the wiring from the fire alarm panel. Operate the alarm.
  • No category recorded per door. Without it, nobody can say whether the door behaved correctly.
  • Emergency release wired through the controller. If the controller fails, so does the way out.
  • Doors not held as assets. A system-level tick hides the one door that was never tested.
  • Credentials never reviewed. Leavers still active and engineer defaults still in place are findings waiting to happen.

See also the fire detection and alarm certificate page for the alarm side of the interface, and the records a scheme audit asks for.

FAQ

Common questions

Is there a handover record the customer can sign?

Yes. A shared handover and acceptance record is used across intruder, CCTV and access control.

Can I record doors that release on a fire alarm?

Yes. Record the check and the result on the visit, and raise a defect if a door does not behave as it should.

Can a failed reader become a quote?

Yes. A fault found on a visit can be raised as a defect and quoted without re-typing.

How do I record the fire alarm release test for each door?

Hold each door as an asset on the site and record the result of the release check per door on the visit. Note the BS 7273-4 category the design gave the door so the next engineer knows what it should do.

Can doors and controllers be held separately?

Yes. Controllers, readers and door releases can each be assets with their own history, so a fault at one door is recorded against that door.

Does the service record show open defects?

Yes. Defects raised on the visit are listed on the job and shown with the record sent to the customer, and they stay open until resolved.

What does it cost?

The built-in templates are included from the Lite seat at £35 + VAT per user per month, with no per-certificate fees and no contract.

Keep every door's history in one place

See the access control records on your own sites in a demo. Onboarding is from £195, quoted individually.